About 698,000 results
Open links in new tab
  1. What is Redlink? - NXP Community

    Redlink (also known as Link Server) is the mechanism used by LPCXpresso to provide a debug connection down to a target MCU. It provides the means to connect to single MCUs or to multiple …

  2. LinkServ or redlink as gdbserver for command-line debugging on i.MX RT

    Jul 10, 2025 · Alternatively, using redlink directly one can simply use it from within gdb... the only disadvantage is that one needs the XML files describing the memory layout (generated by MCUX …

  3. Using the command line flash programming tool - NXP Community

    crt_emu_cm_redlink -flash-load-exec "LPC11U68_App.axf" -vendor=NXP -pLPC11U68 Note: A simple way of finding the correct command and options, is to use the GUI Flash Utility, the completion dialog …

  4. How to make redlinkserv work in the command line? - NXP Community

    Sep 2, 2017 · This is confusing as a NXP user said that we should not need to manually start it with crt_emu_cm_redlink. So at this point I've been trying to use python to open a redlinkserv process in …

  5. Link Server in WSL - NXP Community

    Jan 14, 2025 · Hello, I am currently using the mimxrt1160_evk, I am trying to get the LinkServer working inside of WSL 2. I have installed LinkServer into my WSL 2 instance also installed a bridge tool for …

  6. Unable to open probe index 1 - NXP Community

    Sep 30, 2024 · Unable to open probe index 1. Error: Probe not open Error: Probe not open at com.nxp.mcuxpresso.core.debug.support.linkserver.redlink.client.RedlinkServerClient.checkServerReply …

  7. RedlinkAPI: Probe not open - NXP Community

    Jun 15, 2016 · Content originally posted in LPCWare by StampVoet on Fri Jul 04 01:41:40 MST 2014 I've tried debugging with JP3 inserted, it now registers as an "LPCLINK2 Redlink" but I'm still not …

  8. MCUXpresso not killing redlinkserv.exe after ... - NXP Community

    Dec 4, 2017 · Although there are some slight differences between redlink in LPCXpresso IDE and MCUXpresso IDE, I would not expect you to see different behaviour of the type you describe. …

  9. LPC54628: Error:Wire ack fault - target connected? - NXP Community

    Jul 13, 2020 · I am using LPC54628 kit. From debugging and programming image using LPC-Link debug probe. In PC, I have installed MCUexpresso to connect with the board via LPC-Link. As a …

  10. Solved: redlink server scripting behaviour - NXP Community

    Jun 20, 2024 · For reference, turns out my particular issue was caused by the data cache, as I was able to mark the 0x60000000 region as uncacheable, and everything worked as intended. Still unsure as …